The 2711P-K7C4A9 is the 700-model terminal of the PanelView Plus 6 range: 6.5 in, 640 x 480 (VGA), active area 132 x 99 mm, 300 cd/m2, with keypad and 100...240V AC input.
The 700 model is the smallest of the 700...1500 family and the only size that keeps a 640 x 480 pixel map while shrinking the front to 193 x 290. A 1000-model application transfers to it unchanged, which is why this catalog number is still specified for compact machines.
| 2711P-K10C4A8 | لوحة مفاتيح، ملون، إيثرنت + RS-232 + 2 USB، مدخل تيار متردد | متوفر في المخزون |
| 2711P-T10C4A8 | شاشة لمس، ملون، إيثرنت + RS-232 + 2 USB، مدخل تيار متردد | متوفر في المخزون |
| 2711P-B10C4A8 | لوحة مفاتيح وشاشة لمس، ملون، إيثرنت + RS-232 + 2 USB، تيار متردد | متوفر في المخزون |
| 2711P-K10C4D8 | لوحة مفاتيح، ملون، إيثرنت + RS-232 + 2 USB، مدخل تيار مستمر | متوفر في المخزون |
| 2711P-T10C4D8 | شاشة لمس، ملون، إيثرنت + RS-232 + 2 USB، مدخل تيار مستمر | متوفر في المخزون |
| 2711P-B10C4D8 | لوحة مفاتيح وشاشة لمس، ملون، إيثرنت + RS-232 + 2 USB، تيار مستمر | متوفر في المخزون |
| 2711P-K10C4A9 | لوحة مفاتيح، ملون، إيثرنت + RS-232 + 2 USB، تيار متردد، CE ممتد | متوفر في المخزون |
| 2711P-T10C4A9 | شاشة لمس، ملون، إيثرنت + RS-232 + 2 USB، تيار متردد، CE ممتد | متوفر في المخزون |
| 2711P-B10C4A9 | لوحة مفاتيح وشاشة لمس، ملون، تيار متردد، ميزات CE ممتدة | متوفر في المخزون |
| 2711P-K10C4D9 | لوحة مفاتيح، ملون، إيثرنت + RS-232 + 2 USB، تيار مستمر، CE ممتد | متوفر في المخزون |
| 2711P-T10C4D9 | شاشة لمس، ملون، إيثرنت + RS-232 + 2 USB، تيار مستمر، CE ممتد | متوفر في المخزون |
| 2711P-B10C4D9 | لوحة مفاتيح وشاشة لمس، ملون، تيار مستمر، ميزات CE ممتدة | متوفر في المخزون |
التطبيق |
طرف المشغل PanelView Plus 6، موديل 700، 6.5 بوصة |
رقم الكتالوج |
2711P-K7C4A9 |
اسم العلامة التجارية |
روكويل |
حجم الشاشة |
6.5 بوصة |
نوع الشاشة |
شاشة TFT ملونة نشطة |
الدقة |
640 × 480 (VGA) |
عمق الألوان |
رسومات ملونة بدقة 18 بت |
منطقة نشطة |
132 × 99 ملم |
السطوع |
300 قرص/م2 |
إدخال المشغل |
لوحة مفاتيح |
شاشة لمس |
غير مجهزة |
لوحة مفاتيح |
22 مفتاح وظيفة F1...F10 و K1...K12، غشاء من الفولاذ المقاوم للصدأ، مليون ضغطة، قوة تشغيل 340 جرام |
منافذ الاتصال |
إيثرنت 10/100، RS-232، 2 مضيف USB، بالإضافة إلى فتحة وحدة اتصال واحدة |
طاقة الإدخال |
100...240 فولت تيار متردد، 50...60 هرتز |
استهلاك الطاقة |
160 فولت أمبير كحد أقصى |
الذاكرة |
512 ميجابايت رام، 512 ميجابايت غير متطايرة (حوالي 79 ميجابايت مجانية لذاكرة المستخدم) |
نظام التشغيل |
Windows CE 6.0 مع ميزات ممتدة |
وحدة تخزين قابلة للإزالة |
فتحة SD قابلة للتبديل السريع، 1784-SDx / 1784-SDHCx |
فتحة اللوحة |
167 × 264 ملم |
الأبعاد |
193 × 290 × 55 ملم |
الوزن |
1.8 كجم تقريبًا |
الإضاءة الخلفية |
CCFL، 50,000 ساعة كحد أدنى عند 25 درجة مئوية، قابلة للاستبدال في الميدان |
بطارية الساعة |
2711P-RY2032 (CR2032)، 4 سنوات كحد أدنى عند 25 درجة مئوية |
درجة الحماية |
NEMA Type 12, 13, 4X داخلي و IP54, IP65 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2711P-UM006 (module specifications) and 2711P-TD001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
PanelView Plus 6 700 model: 6.5 in color TFT, 640 x 480 (VGA), active area 132 x 99 mm, 300 cd/m2. Operator input is the membrane keypad - 22 function keys F1...F10 and K1...K12, stainless-steel membrane, 1 million presses, 340 g operating force - with no touch layer, so every screen has to be reachable by key navigation.
The front measures 193 x 290 and the cutout is 167 x 264 mm; depth behind the panel is 55 mm, and the communication module in the rear slot adds about 28 mm more.
Only keypad and keypad/touch fronts use the wider 167 x 264 mm opening; a touch front needs 154 x 220 mm. Cutting the touch opening in a panel intended for a keypad model leaves the keypad front unable to seat, so settle the catalog number before the enclosure is fabricated.
Display: 6.5 in, 640 x 480 (VGA), 18-bit color, active area 132 x 99 mm, 300 cd/m2. The backlight is a cold-cathode fluorescent lamp rated 50,000 hours minimum at 25 deg C and is field replaceable on 700...1500 terminals - unlike the LED backlight of the 400 and 600 models.
Input power: 100...240V AC (50...60 Hz), 160 VA max. The AC terminals draw 160 VA maximum at 100...240V AC, so check the panel feed and any shared circuit before adding this terminal to an existing enclosure.
Mass: 1.8 kg approx. for this front. A panel door carrying this size of terminal plus the enclosure load has to be held by the mounting levers, so confirm panel thickness is inside the lever range.
Environment: front rated NEMA Type 12, 13 and 4X indoor and IP54/IP65, relative humidity 5...95%% noncondensing, 15 G shock at 11 ms, operating altitude up to 2000 m.
CCFL thermal behaviour: below 10 deg C internal temperature the backlight is overdriven at full rated current for at least five minutes to warm the display, and above 60 deg C it is underdriven to 40%% or less of full brightness. Temperature control affects intensity only, so a cold cabinet start is not a fault.
Cut the opening 167 x 264 mm from the template shipped with the terminal. Leave at least 100 mm clear behind the panel where a communication module is fitted, and keep the lower rear face clear for the power terminal block and the earth conductor.
The DC terminal is not isolated from functional earth in this range either, so the supply must be SELV or Class 2 and the FE terminal must be wired. An AC supply needs protective earth on the three-position block.
Tighten the mounting levers evenly until the gasket compresses, then re-check the four corners; one uneven lever shows as an IP65 leak at the corner of a 6.5 in front.
DC: 18...32V DC, 70 W maximum, 2.9 A at 24V DC, 39 W typical. AC: 100...240V AC, 50...60 Hz, 160 VA maximum.
Power blocks accept 0.3...2.1 mm2 (22...14 AWG) 90 deg C copper at 0.45...0.56 N m (4...5 lb in); two wires per terminal are allowed up to 1.3 mm2 (16 AWG).
Functional earth is mandatory: the DC negative is internally tied to the FE terminal and the AC input relies on protective earth for EMC. Route the earth conductor first and torque it before closing the terminal cover.
The real-time clock runs from a 2711P-RY2032 coin cell, 4 years minimum at 25 deg C, accurate to about plus or minus 2 minutes per month.
Standard on this catalog number: Ethernet 10/100 with auto MDI/MDI-X, RS-232, two USB 2.0 host ports. The rear slot accepts a communication module for DH+/DH-485 or ControlNet, scheduled or unscheduled.
Ethernet carries EtherNet/IP tag access, FactoryTalk ViewPoint clients and project download; RS-232 covers DF1, ASCII, bar-code readers and printers; a USB flash drive moves applications and data logs without a network.
FactoryTalk View Machine Edition version 6.10 or later is required. The hot-swappable SD slot takes 1784-SDx and 1784-SDHCx cards for file transfer, firmware upgrade and data logging.
USB circuit parameters for nonincendive field wiring are 5.25V DC, 1.68 A short-circuit current, 10 microfarad and 15 microhenry.
Three choices define this terminal: operator input (keypad, touch, or keypad and touch), input power (AC or DC), and the operating system suffix (8 = Windows CE 6.0, 9 = Windows CE 6.0 with extended features). Color, VGA resolution, 512 MB memory and the 55 mm depth are common to every row.
Suffix 9 adds the extended Windows CE 6.0 features; display, power and cutout stay the same, so a 9 model replaces an 8 model on the same panel opening when the application needs the extra features.
هل يحتوي 2711P-K7C4A9 على شاشة لمس؟
لا. هذا الطرف هو لوحة مفاتيح فقط؛ النسخة التي تعمل باللمس بنفس الحجم والإمداد هي النظير T في جدول الكتالوج أعلاه.
ما هو القطع الذي يحتاجه 2711P-K7C4A9؟
167 × 264 ملم. يبلغ قياس الواجهة الأمامية 193 × 290 والعمق 55 ملم.
ما هي دقة شاشة 2711P-K7C4A9؟
640 × 480 (VGA)، 18 بت لون، منطقة نشطة 132 × 99 ملم، 300 قرص/م2.
كم تستهلك طاقة 2711P-K7C4A9؟
100...240 فولت تيار متردد، 50...60 هرتز، 160 فولت أمبير كحد أقصى.
هل الإضاءة الخلفية لـ 2711P-K7C4A9 قابلة للاستبدال؟
نعم. تستخدم أطراف 700...1500 إضاءة خلفية CCFL قابلة للاستبدال في الميدان مصنفة بـ 50,000 ساعة كحد أدنى عند 25 درجة مئوية؛ تستخدم موديلات 400 و 600 إضاءة خلفية LED غير قابلة للاستبدال.
ما هي الذاكرة التي يمتلكها 2711P-K7C4A9؟
512 ميجابايت رام و 512 ميجابايت ذاكرة غير متطايرة، حوالي 79 ميجابايت مجانية للتطبيق.
هل يمكن تشغيل تطبيق موديل 700 على موديل 2711P-K7C4A9؟
نعم. كلاهما يستخدم خريطة بكسل 640 × 480، لذا يتم نقل تطبيق FactoryTalk View ME دون إعادة تصميم؛ القطع وحجم الواجهة الأمامية هما ما يتغيران.
ما الذي يحل محل بطارية الساعة في 2711P-K7C4A9؟
2711P-RY2032، خلية عملة معدنية CR2032 مكافئة، 4 سنوات كحد أدنى عند 25 درجة مئوية.